in Russianin Englishin Finnish

AutoLog® OEM-PLCs
Introduction | AL-4 | AL-8 | AL-10SP | AL14LP | AL-16 | AL-20 | AL-32 | AL2000S |

AutoLog® 14LP

Low Power model, which is designed to be used in low power applications, outside the power network. Operates with 12/24VDC accumulator. Accumulator can be charged using solar panel, exchangeable accumulators etc. AL14LP can also operate using power from network. AL14LP has two serial ports. AL14LP has four power modes and it can be configured to power only part of its components.


Digital inputs (DI) 8 pcs
12/24 VDC / max. 8 mA / PNP / opto-isolated
Digital outputs (DO) 8 pcs (NPN) + 1pcs (PNP)
12/24VDC / max. 1A / group max. 4A / opto-isolated
1 pcs PNP output for external sensor powering
Analog inputs (AI) 0-4 pcs,
12-bit plug-in pointwise analog input modules
Pt100 (-50..150°C / 0..500°C / -250..750°C),
0..5mA, 0..20mA, 4..20mA, KTY10 (-50..150°C),
NTC (-5..50°C), 0..2V, 0..5V, 0..10V, -10..10V,
RMS 40VAC/25VAC/ 0.25VAC etc.
(Power from analog inputs can be closed if not used)
Serial ports 2 pcs
SER1 : RS 232, (RJ45)
SER2 : RS 232, (RJ45)
(Power from serial ports can be closed if not used)
Modbus RTU -communication Modbus can run simultaneously in both serial ports. Independent setting for both serial ports,
Master/Slave, 300-115200bps
I2C-port 1 pcs
for HMI, iButton, etc. (Power from I2C port can be closed if not used)
HMI -user interface Local user interface can be connected through I2C-port or serial port. Variety of different models from small, character displays to multi-featured Windows CE based graphical touchscreens, with Web Studio SCADA development tool support. Look more from AutoLog® HMI -pages.
Battery backup Yes
Application program capacity 512kB FLASH, 8000 programming lines
Program instructions / functions Over 260 instructions / functions
Logical, arithmetic, comparison, timer/counter, sequence program, reporting, queue, FIFO, PID...
PID controllers 32 build-in PID controllers
Programming tool (PC) (AutoLog®) ALProWin, instruction list & ladder, symbolic names, trends, monitoring tables, binary and Modbus programming.
Remote programming PLCs can be programmed remotely through any transmission media, which supports Modbus protocol. e.g. Radio Network, GSM Data, RS-485.
Data memory RAM 512kB
Data logging PLC can save time-stamped measurement or any data into its memory. E.g. 10 time-stamped measurements x 3000 records.
Clock/Calendar Yes (can be set remotely)
UPS connector Yes, using AL-UPS card
Enclosure Default: DIN -rail mounting with metal cover, IP20
Opt 2 : plastic box, IP65
Opt 3: metal box. Ask more!
Size (w x h x d) AL14LP: 225 X 125 X 65 mm
Weight ~0,3 kg
Operating temperature** AL14LP: -30...+70 °C
Storage temperature** AL14LP: -40...+80 °C
Power supply 12 / 24VDC or 10/18VAC max. 5VA
Power consumption Power consumption depends on the used power save mode and application. Power save modes are:
- Run mode. Power cons. depends on the powered hardware components: analog inputs, I2C, serial ports, LEDs, external power, 5.6mA - 20mA
- Idle mode, clock, digital input and serial port interruption, 2.2mA
- Stop mode, clock and digital input interruption, 1.2mA
- Clock interruption mode, 140µA
EMC Immunity according to EN50082-1 & EN50082-2
Emissions according to EN50081-1 & EN50081-2


Order information:

AutoLog® 14 LP
 
product name description code
AL14LP AutoLog® 14LP PLC 900670


Optional modules and accessories:
 
SCADA, control room software Web Studio / any SCADA on market that supports Modbus ( 99% of SCADAs support Modbus RTU protocol). Look Web Studio!
Analog input modules
(0-4 pcs)
Pt100 ( -50..150°C )
Pt100 ( 0..500°C )
Pt100 ( -250..750°C )
0..5mA
0..20mA
4..20mA,
KTY10 (50..150°C),
NTC (-5..50°C),
0..2V,
0..5V,
0..10V,
-10..10V,
RMS 40VAC
RMS 25VAC
RMS 0.25VAC
900781
900782
900784
900795
900799
900800
900797
900796
900788
900785
900786
900790
900809
900807
900808
Touch screens
(serial port connection)
AL56CE-HMI  (WinCE 5.6"TFT)
AL121CE-HMI (WinCE 12.1" TFT SVGA)
(Supports Web Studio SCADA development tools)
945122
945124

 
HMI interfaces
(I2C -port connection)
AL1093F (2 x 16 characters)
AL1095A (8 x 21 characters / 128 x 64 pixels)
900860
900850
ALProWin PC based AutoLog® PLC programming tool 941020
Wireless I/O Wireless I/O master and slave modules ask
Radio modem External radio modem for wireless communicating and also remote programming of PLC. ask
GSM modem External GSM modem. ask


Please call or send e-mail to get more information!

FF-Automation
Eräkuja 2
01600 Vantaa
Finland
Tel: +358 10 2190 500

 


Copyright FF-Automation Oy. All Rights Reserved