AutoLog® OEM-PLCs
Introduction | AL-4 | AL-8 | AL-10SP | AL14LP | AL-16 | AL-20 | AL-32 | AL2000S |

AutoLog® 2000S

AutoLog® PLC is designed for large size projects where large quantity of I/Os are needed. Modular, freely selectable plug-in I/O modules are inserted into metal rack. CPU card and power is also inserted into same rack. CPU card doesn't have own I/O. P-model CPU has build-in power, so it can be used in small MR3 rack.




CPU module CPU2000S
CPU2000P, 24VDC, used in MR-mini kehikossa.
Digital inputs (DI) (0) 16 - 256 pcs
24 VDC, 230VDC/AC max. 8 mA
Digital outputs (DO) (0) 16 - 256 pcs
24 VDC / max. 1A, 230V / max 4A
Analog inputs (AI) (0) 16 - 256 pcs
PT100, KTY10, 0(4)...20mA, 0...5V, 0...10V, etc.. Input range can be programmed pointwise using configuration software.
Analog outputs (AO) (0) 16 - 256 pcs
0..20mA, 4..20mA, 0..5V / 0..10V
Serial ports 3 pcs
SER1 : RS232
SER2 : RS232
SER3: RS485 (isolated)
Modbus RTU -communication Modbus can run simultaneously in all serial ports. Independent setting for all serial ports,
Master/Slave, 300-115200bps
I2C-port 1 pcs
HMI, iButton, etc.
HMI -user interface Local user interface can be connected through I2C-port or serial port. Variety of different models from small, character dislays to multi-featured Windows CE based graphical touchscreens, with Web Studio SCADA development tool support. Look more from AutoLog® HMI -pages.
Battery backup Yes
Application program capacity 8000 programming lines
Program instructions / functions Over 260 instructions / functions
Logical, arithmetic, comparison, timer/counter, sequence program, reporting, queue, FIFO, PID...
PID controllers 8 build-in PID controllers
Programming tool (PC) (AutoLog®) ALProWin, instruction list & ladder, symbolic names, trends, monitoring tables, binary and Modbus programming.
Remote programming PLCs can be programmed remotely through any transmission media, which supports Modbus protocol. e.g. Radio Network, GSM Data, RS-485.
Clock/Calendar Yes (can be set remotely)
UPS connector Yes, using AL-UPS card
GSM/GPRS modem Optional external GSM/GPRS modem.
Enclosure metal rack, look mounting racks for more info.
Operating temperature** 0...+55 °C
Storage temperature** -40...+70 °C
Power supply 24VDC, 110/230VAC VAC max.100VA
EMC Immunity according to EN50082-1 & EN50082-2
Emissions according to EN50081-1 & EN50081-2


Order information:

AutoLog® 2000S/P CPU, I/O cards, Mounting racks, Powers
product name description code
AL2000S (CPU) AutoLog® 2000S CPU card 902200
AL2000P (CPU) AutoLog® 2000P CPU card (for MR3-mini) 902206

AutoLog® 2000 Mounting Racks
MR-mini Mounting Rack for 3 I/O cards, needs P-type CPU card. 902158
MR-mini (with covers) Mounting Rack for 3 I/O cards with covers, needs P-type CPU card. 902159
MR3 Mounting Rack for 3 I/O cards (115 VAC) 902151
MR3 Mounting Rack for 3 I/O cards (220 VAC) 902152
MR3 Mounting Rack for 3 I/O cards (24 VDC) 902153
MR5 Mounting Rack for 5 I/O cards 902150
MR11 Mounting Rack for 11 I/O cards 902154
MR16 Mounting Rack for 16 I/O cards 902156
Expansion cables
FC50, FC100
Extra I/O expansion rack can be connected using expansion cable.
Flat cable 50cm and 100cm
902100
902110

AutoLog® 2000: I/O cards

Digital input cards (DI)
DIC32DC 32 pcs inputs, 24VDC, max. 8mA, isolated in groups of 16 inputs. 902220
DIC32AC 32 pcs inputs, 24VAC, max. 8mA, isolated in groups of 16 inputs. 902224
DIF16 16 pcs inputs, 24VDC, automatic failure indication 902228

Digital output cards (DO)
DOC32EP/FP 32 pcs outputs, 24...40VDC/VAC, max. 1A, FET type outputs can be connected parallel. EP -model has electrical protection, FP-model has fuze protection. 902240
902244
ROC16K 16 pcs relay outputs, 24...250VAC, max. 4A, pointwise isolation. 902260
OOC16 16 pcs relay outputs, 24...250VAC, 0.6A solid-state outputs, pointwise isolation 902264
DOF16 16 pcs outputs, 24VDC, automatic failure indication 902248

Digital input/output cards (DIO)
DIO32 16 pcs inputs, 24VDC, max. 8mA, isolation in groups of 16 inputs.
16 pcs outputs, 24...40VDC/VAC, max. 1A, FET type outputs can be connected parallel. Electrical protection.
902266

Analog input cards (AI)
AIC8 8 - 16 pcs inputs, 0..480mV, 0..20mA, 4..20mA, 0..5V, 0..10V, Pt100, KTY10. Input type and range in defined pointwise using AlProWin program. 902273
TIC8 Termocouple input, 8 inputs (B, E, K, J, R, S, T), Input type and range in defined pointwise using AlProWin program. Group isolation. 902274
MIC16 16 pcs current inputs, 0..20mA OR 4..20mA. Pointwise isolation. 902272

Analog output cards (AO)
MOC16 16 pcs current outputs, 0..20mA OR 4..20mA. Pointwise isolation. 902277

Analog input/output cards (AIO)
AIO74 7-14 pcs inputs, 0..480mV, 0..20mA, 4..20mA, 0..5V, 0..10V, Pt100, KTY10. Input type and range in defined pointwise using AlProWin program.
4 pcs outputs, 0..20mA OR 4..20mA. Group isolation.
902270


Optional modules and accessories:  
SCADA, control room software Web Studio / any SCADA on market that supports Modbus ( 99% of SCADAs support Modbus RTU protocol). Look Web Studio!
Touchscreens
(serial port connection)
AL57CE-HMI  (WinCE 5.7" SNT QVGA)
AL121CE-HMI (WinCE 12.1" TFT SVGA)
(Supports Web Studio SCADA development tools)
945122
945124
 
HMI interfaces
(I2C -port connection)
AL1093F (2 x 16 characters)
AL1095A (8 x 21 characters / 128 x 64 pixels)
900860
900850
ALProWin PC based AutoLog® PLC programming tool 941020
Radio modem External radio modem for wireless communicating and also remote programming of PLC. ask
GSM modem External GSM modem, look also GSM-20 model if you need GSM modem! ask